Home Page>>Renhe Sales>>Parallel Switchgear
 

Capacity (KVA)

Model (A)

Price (USD)

150-275

400

 

276-425

630

 

426-500

800

 

501-650

1000

 

651-888

1250

 

881-1050

1600

 

1051-1310

2000

 

1311-1640

2500

 

1641-2100

3200

 

2101- 4000  

Notes
   (1) ABB Switch Paralleling system.
   (2) The above price is subject to the single Genset.
   
e.g. the price of the APS for paralleling 2 sets of Gensets of 630A is 48,000*2=96,000
   (3) The above price is on Ex-work terms.
  
(4) Terms of payment : 30% advance payment paid by T/T, and the remaining 70% to be paid by L/C.

● Components:
The APS contains a Paralleling Control Switchgear and an Export Box. Each Genset should be equipped with a Paralleling Control Switchgear. Attached please find the drawings for the brand, specification and model of switch and dimension of the switchgear.

● Features, functions and scope of application:
2.1 Automatically loading, unloading and sharing load. The system monitors the Gensets supply automatically.
2.2 Easy to operate. The working status is very steady.
2.3 Full protection functions, including: Reverse current, over current, Genset fault trip, overload (separated from switch), voltage fault and emergency-stop. And other protection functions are available upon request from the end-users.
2.4
Basic function:
     (a) Manual start up.
     (b) Isochronous display.
     (c) Automatic synchronizing test.
     (d) Automatic paralleling.
     (e) Automatic sharing loads.
     (f) Auto unloading: when 2 or more Gensets are parallel running, the APS will transfer the load to the other Genset when one of the Gensets
          stops. When the load is approaching 0, the breaker trips automatically.
2.5
Optional functions
     (a) Auto start the Genset
     (b) Select the Priority Genset
     (c) Mains high voltage default examining.
     (d) Auto-start Genset upon the mains failure.
     (e) Auto-start Genset upon the mains failure.
     (f) Monitors the paralleling.
2.6
Optional functions
As for their multi-functions, the APS will meet the high automatization requests from the users, e.g. Airports, Hotels, office buildings, hospitals and telecommunication departments.
2.7
Optional functions
The APS can be used directly on the Gensets of different brands and models. Note the following please:
(a) The Gensets should contain an independent Electric Governor, AVR with voltage decline port. Otherwise the governor or voltage regulator should be changed or added, e.g. Cummins PCC series.
(b) The Gensets should contain an auto-start panel, otherwise, the Gensets should be changed or added, e.g. F G Wilson 1000 Series control panels.
(c) Should the Gensets be changed or added, more fees will be charged.
2.
8The electric components are of high quality. Refer to the List.

● Technical data:
Rated Working Voltage: AC 380 (Main Circuit)
Control Circuit: AC380V AC220V DC24V
DC12V
Rated Frequency: 50Hz
Phase:  3 Phase -4 Wires system
Rated Insulation Voltage: 660V

● Working Conditions:
Ambient Temperature: -15℃~+40℃ (Average Temperature : ≤35℃)
Relative Humidify : < 90%
+20℃< 50%+40℃
Attitude Height: ≤2000M
And be sure to install the APS in the conditions without shock or vibration or corrosion.

● Framework:
Framework of the APS is connected by means of assembling and partly-welding. The unit switchgear is separated assembled and remains functioning separately, e.g. the Control Unit, Breaker Unit. Main Line Unit and Cable Unit. Steel sheet or Insulation sheet is adopted to separate the units.

● Main line:
The Main Line is made of high conductive copper so as to increase the conduction ability.

● Main Control units and functions:
Auto Synchronizing Controller: Installed in the Output Box, the controller compares the phase position and frequency of the Genset which is not paralleled with the Busbar Wire. It gives the current signal when phase difference occurs. And the signal will raise or lower the Genset speed according to the Gensets’ phase angle difference compared with the Busbar wire. The size of the signal is pro rata with the phase position. When the phase and frequency can match the “lock” period within a limited range, the Controller will close the contacts which are open at normal time and close the loaded breaker by the Relay. The controller is capable of displaying the speed and the synchronizing display.
Paralleling Central Controller
HARSEN-ASYN205: The controller works as a governor and power balancer. When not paralleling, the controller can receive the signals from the Auto synchronizing Controllers and change the speed of the Genset, so as to match the phase and voltage frequency of the Gensets and Busbar Wire. After paralleling, the Controller compares the Real Power and voltage frequency with the pre-set frequency. Then after adding the signals, the Controller outputs the speed-control signals so as to parallel the Gensets with the Real load balanced.

● Meters and functions:
P.F. Meter: Monitors the percentage of the Real power comparing with the Apparent Power.
AC Current Meter: 3 meters monitor the 3 phase current simultaneously.
AC Voltage Meter: Monitors the line voltage or phase voltage selected by the “Voltage-select” switch.
Frequency Meters: Monitors the voltage frequency of the Genset.

Meters and functions of the Export Box:
P. F. Meter: monitor the percentage of the Real Power comparing with the Apparent Power.
AC Current Meter: Monitor the 3 phase current of the total load.
AC Voltage: Monitors the line voltage and phase voltage of the Busbar Wire.
Frequency Meter: monitors the voltage frequency of the Busbar Wire.

● Status and fault light of the APS:
Generator Fault: Low Oil Pressure or High water temperature fault when the light goes on. The signal is delivered by the Genset control panel.
Reverse Power Fault: Reverse fault occurs between paralleled Gensets when the light goes on, and the figure exceed the control range.
E-stop: The indicating light goes on when press the E-stop button; Breaker trips immediately and paralleling Switchgear stops functioning.
Voltage Fault: when the output voltage is high/ low, the lights goes on.
Overload: the load of the Genset exceeds the pre-set range when the light goes on.
DC Source: The DC source is connected when the light goes on.
Generator Running: The Genset is running normally when the light goes on.
Circuit Breaker closed: The loading breaker is closed when the light goes on.
Raise: the speed of the engine raises when the light goes on.
Lower: the speed of the engine lowers when the light goes on.
Soft Load: Press the “Idle Load” when the light goes on.
Ute: Press the “mute” Button when the light goes on.

● Selectors and controller on the Panel:
Voltage selector: Rota table Selector makes the voltmeter display the phase voltage and line voltage of the Genset.
Paralleling mode Selector: When in “MAN” mode, the operator can adjust the frequency and circuit breaker by the buttons on the panel; when placed in “OFF” mode, the operator can’t adjust the circuit and speed of the Gensets by the buttons on the panel; when in “AUTO” mode, the APS can control the circuit breaker and adjust the speed of the Gensets to balance the Real load or the synchronize alternators.
Control Mode Selector: when in “MAN” mode, the operator can start or stop the Genset by “START” or “STOP” button; when placed in “OFF” mode, the operator can’t start or stop the Genset by buttons on the panel; when in “AUTO” mode, the APS central controller can control the Gensets according to the Mains fault, load of Gensets and other fault.
Raise: When in “MAN” place, the speed of the Genset will raise when the light goes on.
Lower: When in “MAN” place, the speed of the Genset will lower when the light goes on.
MUTE: When the default occurs, the horn alarm will buzz for alarming. Press the “Mute” button to silence the horn.
Reset: When default occurs during paralleling, the default status will be locked. After solving the problem, press “Reset” to release the situation.
Start: When in “MAN” mode of the Gensets, press “Start” to start the Genset by sending the signal to the Genet Panel.
Stop: When in “MAN” mode of the Genset, press “Stop” to stop the Genset by releasing the signals to the Genset Panel.

● APS protection:
Reverse Power Delay Protection: The Reverse Power Relay monitors the Real Power of the Genset. If the reverse Power reaches the pre-set level(-2%~ -20%) within pre-set limited time (0-30s), the Load Breaker will open the circuit and stop the Genset by closing the remote signals to avoid the other Genset mistakenly started by the one. The pre-setting is normally as 5s and 5% reverse power.
Genset fault Protection: When the running Genset has fault occured, the control panel of the Genset will send the signals to the APS. The Load Breaker inside the APS will open the circuit and stop sending the remote starting signals.
Over/Under Voltage Protection: Over/Under Voltage Relay monitors the output voltage of the Genset. If the output voltage exceeds the pre-set level (AC 220V -15%-0% or 0-15%) within pre-set limited time (0-30s), the load breaker will open the circuit and stop the Genset by closing the remote signals.
Over Power Protection: The Over Power Protection Relay monitors the Real Power of the Genset. If the output voltage exceeds the pre-set level (AC 220V -15%-0% or 0-15%) within pre-set limited time (0-30s), the load breaker will open the circuit and stop the Genset by closing the remote signals.
Emergency Stop: when the APS default occurs, the operator will push the E-Stop button to open the circuit in order to stop the remote start signals.

● Selector Switch and operation Switch:
Voltage Selector: Rotate the Selector to display the phase voltage and line voltage of the Busbar Wire by the voltmeters.
Current Selector: Rotate the Selector to display the phase current of the Busbar Wire by the current meters.
Priority Load Selector
1#-OFF-2#: When placed as 1#, the priority Genset is No. 1, and No. 2 Geneset is the auxiliary power; when placed as 2#, the priority Genset is No.2. and No. 1 Genset is the auxiliary power; when placed as “OFF”, the Gensets will be started manually.

● Main Parts List of Paralleling Switchgear:

Item

Name

Model

Quantity

1

Paralleling Central controller

ASYN205

1

2

Voltmeter

V

1个

3

Ampere meter

A

3

4

Frequency Meter

HZ

1

5

Power Factor Meters

COS

1

6

KW Meters

KW

1

7

Voltage Selector

BACO-V

1

8

MOA Selector

BACO-V

2

9

Button Switch

 

4

10

Emergency Stop

 

1

11

Protection Module

HS8000

1

12

Running Status Indication module

Harsen-MON12L

1

13

Trimmer Potentiometer

AMBAC-

1

14

Circuit Breaker

ABB

1

15

Relay

OMRON-MY4

1

16

Enclosure

2000*700*800

1

Note: The above quantity ×N is the total units for paralleling.


● Main Part List of Export Box:

Item

Name

Model

Quantity

 

Isochronous display controller

Harsen-KSQ105D

1

 

Programmer optional

LOGO!

1

 

Voltmeter

V

1

 

Trimmer Potentiometer

A

1

 

Voltage Selector

BACO-V

1

 

Current Selector

BACO-A

1

 

Relay

OMRON-MY4

1

 

Timer

OMRON-MY4

1

 

Output Board

SC-PCB

1

 

Enclosure

2000*800*800

1

Order Information

Contact person

*

Tel

*

EMAIL

*

Quantity

*

Remarks and special requests

      

Purchase Remarks:
Welcome to our Production Department. We will provide the following service items for you at your placing a purchase order.
 Send professional people to the working site for installation guide, adjustment and commissioning test.
 Technical training: Academic and practical training on spot/ complimentary technical training in supplier’s place
 Necessary spare parts
 Guarantee. The guarantee shall be valid for the period of twelve months or 1000 hours whichever comes first. The guarantee shall cover    against manufacture defect, bad material and workmanship only.
Service hotline: 800-890-8345
(The above items are subject to Beijing Renhe Epoch Mechanical & Electrical Equipment Co., Ltd without prior notification.)